{"id":71,"date":"2016-07-16T11:11:31","date_gmt":"2016-07-16T03:11:31","guid":{"rendered":"http:\/\/www.t-med.cn\/en\/?p=71"},"modified":"2016-08-04T14:59:18","modified_gmt":"2016-08-04T06:59:18","slug":"us-osteomed-craniofacial-quick-fix-system","status":"publish","type":"post","link":"https:\/\/www.t-med.cn\/en\/?p=71","title":{"rendered":"OsteoMed Cranio and Maxillfacial Fixation System"},"content":{"rendered":"

1. OsteoMed Cranio and Maxillfacial Fixation System\uff08product name\uff1aFast-FlapTM)<\/strong><\/span><\/p>\n

\u00a0 \u00a0Product standard:\u00a0<\/strong><\/span><\/p>\n

Import product standard YZB\/USA 6125-2012\u300aCranio and Maxillfacial Fixation System\u300b<\/span><\/p>\n

\u00a0 \u00a0Struture and performance\uff1a<\/strong><\/span><\/p>\n

It\u00a0is composed of metal plates and metal screw, uses Ti6A14V ELI titanium alloy materials that meets the standard of ASTM F136. Product\u00a0surface is without color. Non\u00a0sterilization condition.<\/span><\/p>\n

\u00a0 \u00a0 \u00a0Scope of application\uff1a<\/strong><\/span><\/p>\n

The product is suitable for cranial and maxillofacial bone trauma or assisting fixation for reconstruction.<\/span><\/p>\n

2.Cranial and maxillofacial trauma fixation system\uff08product name\uff1aOsteoMed CFxTM)<\/strong><\/span><\/p>\n

\u00a0 \u00a0 \u00a0Product standard\uff1a<\/strong><\/span><\/p>\n

Import product register standard YZB\/USA 6126-2012 \u300aCranial and maxillofacial truma fixation system\u300b<\/span><\/p>\n

\u00a0Struture and performance\uff1a<\/strong><\/span><\/p>\n

The product has metal\u00a0plates, titanium mesh and metal screw. Metal screw and partial metal plates is made of Ti6A14V ELI titanium alloy materials according to the standard of ASTM F136, titanium mesh and partial\u00a0metal plates is made of pure titanium material \u00a0which meets the standard of\u00a0ASTM F67, details as shown in the product size\u00a0specification list. Product surface is without color. Non\u00a0sterilization condition.<\/span><\/p>\n

\u00a0 \u00a0 Scope of application\uff1a<\/strong><\/span><\/p>\n

This product is suitable for the skull fracture,\u00a0facial trauma fracture reconstruction.<\/span><\/p>\n

3.Cranial and maxillofacial plate fixation system\uff08product\uff1aOSA System TM\uff09<\/strong><\/span><\/p>\n

\u00a0 \u00a0 Product standard\uff1a<\/strong><\/span><\/p>\n

YZB\/USA 6512-2012″Cranial and maxillofacial plate fixation system”<\/span><\/p>\n

Struture and performance\uff1a<\/strong><\/span><\/p>\n

Product is composed of metal plates and metal screw, metal plates use grade 2 pure titanium in accordance with ASTM F – 67 , the screw use Ti6A14V ELI titanium alloy materials that meets the standard of ASTM F136 . Product surface is without color. Non\u00a0sterilization packaging.<\/span><\/p>\n

\u00a0 Scope of application\uff1a<\/strong><\/span><\/p>\n

This product is applicable to the midface, skull trauma, craniofacial surgery, reconstructive surgery, and the\u00a0jaw surgery for upper and lower jaw.<\/span><\/p>\n

4.Cranial and maxillofacial fixation system \u00a0[M3 trauma Fixation System(Anodized)]<\/strong><\/span><\/p>\n

\u00a0 Product standard\uff1a<\/strong><\/span><\/p>\n

YZB\/USA 0926-2014″Cranial and maxillofacial fixation system”<\/span><\/p>\n

\u00a0 Struture and performance\uff1a<\/strong><\/span><\/p>\n

The production is composed of cranial and maxillofacial fixation plate and screw, the fixed plate is made of grade\u00a01, grade 2, grade 3 and grade 4 pure titanium material that meets the ISO5832-2 standard ; the screw adopt Ti6A14V titanium alloy material that meets the appropriate ISO5832-3 standard, specific list as shown in the specifications, the pure titanium and titanium alloy products surface is treated by anodic oxidation. Non sterilization packaging.<\/span><\/p>\n

\u00a0 Scope of application\uff1a<\/strong><\/span><\/p>\n

Suitable for cranial and maxillofacial fracture internal fixation.<\/span><\/p>\n

\u00a0<\/strong><\/span><\/p>\n

5\u3002Titanium mesh\u3010M3 mesh trauma Fixation System(Anodized)]<\/strong><\/span><\/p>\n

Product standard\uff1a<\/span><\/p>\n

YZB\/USA 0924-2014\u300aTitanium mesh\u300b<\/span><\/p>\n

Struture and performance\uff1a<\/strong><\/span><\/p>\n

It is made of grade\u00a01, grade 2, grade 3 and grade 4 pure titanium material that meets the standard of ISO5832-2. \u00a0Details\u00a0as shown in the specifications list, the surface is\u00a0treated by anodic oxidation .\u00a0Non sterilization package.<\/span><\/p>\n

\u00a0 \u00a0Scope of application\uff1a<\/strong><\/span><\/p>\n

Suitable for cranial and maxillofacial fracture internal fixation.<\/span><\/p>\n

\"OST8\"<\/a><\/p>\n

\"OST3\"<\/a><\/p>\n

\"OST5\"<\/a><\/p>\n

\"OST7\"<\/a><\/p>\n

\"OST4\"\"OST6\"<\/a><\/p>\n

\"OST1\"<\/a><\/p>\n

\"OST2\"<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"

1. OsteoMed Cranio and Maxillfacial Fixation System\uff08product name\uff1aFast-FlapTM) \u00a0 \u00a0Product standard:\u00a0 Import product standard YZB\/USA 6125-2012\u300aCranio and Maxillfacial Fixation System\u300b \u00a0 \u00a0Struture and performance\uff1a It\u00a0is composed of metal plates and metal screw, uses Ti6A14V ELI titanium alloy materials that meets the standard of ASTM F136. Product\u00a0surface is without color. Non\u00a0sterilization condition. \u00a0 \u00a0 \u00a0Scope of application\uff1a The product is suitable for cranial and maxillofacial bone trauma or assisting fixation for reconstruction. 2.Cranial and maxillofacial trauma fixation system\uff08product name\uff1aOsteoMed CFxTM) \u00a0 \u00a0 \u00a0Product standard\uff1a Import product register standard YZB\/USA 6126-2012 \u300aCranial […]<\/p>\n","protected":false},"author":1,"featured_media":226,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4,2],"tags":[],"_links":{"self":[{"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=\/wp\/v2\/posts\/71"}],"collection":[{"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=71"}],"version-history":[{"count":4,"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=\/wp\/v2\/posts\/71\/revisions"}],"predecessor-version":[{"id":273,"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=\/wp\/v2\/posts\/71\/revisions\/273"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=\/wp\/v2\/media\/226"}],"wp:attachment":[{"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=71"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=71"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.t-med.cn\/en\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=71"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}